DYXZ-01 DYXZ-02


3 Phase Detector Rotation tester

Non-Contact Phase Sequence Detector Meter

Indicator Digital LED Buzzer



The difference between 01 and 02

01Added a function "Motor Rotation detection"Non-contact rotating magnetic field Indication

DYXZ-01 can dectect rotation of single phase and three phase motor. But can not detect motors controlled by frequercy converter


The common function of 01 and 02 is:

(1) Phase Detection

(2) Live Voltage Detection

(3) Phase missing Detection



Product Feature:


1.DYXZ-02 non-contact phase rotation tester designs for quick , easy and accurate detection of three phase sequence in motor installation and repair . The non-connection to insulated conductor avoids uncertain and difficult connections to bare high voltage wires

2.This is a phase detector, designed to perform phase sequence checks and live line checks of a 3-phase circuit using a static induction voltage clip.

3.The static induction voltage clips are used to be able to clip on a cladded wire.It is small with a CAT 600V safety rating.

Red LED lamps are used to make the indication visible in dimly lit areas.The direction of phase sequence can be checked easily using the LED lamps, which blink in order.





Packing list:

Phase Detector: *1

Accessory bag:*1

Certificate of conformity *1

English manual*1



Specifications


1). Basic Specifications

Function

Phase detection (positive/negative)

Voltage detection method

Static induction

Object to be connected

Insulated wire (nominal sectional area of the conductor: 2 to 120mm2,

finished outer diameter: up to 17mm)

Performance-guarantee voltage range

3-phase, 70V to 600 VAC (sine wave,continuous)

Operating frequency range

45Hz to 66Hz

2). Display

Phase-detection

indication

Positive phase sequence:

The four phase-sequence lamps blink order (clockwise) and the buzzer sounds intermittently.

Negative phase sequence:

The four phase-sequence lamps blink in order (counterclockwise) and the

buzzer sounds continuously.

Line-voltage indication

R-S lamp, S-T lamp

Power indication

Power ON lamp: lights up (Power ON)

blinks (Battery Low)


3). General Specifications

Operating temperature and humidity

-10 to 40(32 to 104), 80%RH or less ( with no condensation)

Storage temperature and humidity

-20 to 60 (-4 to 140), 80%RH or less (with no condensation)

Location for use

Altitude up to 2000m(6562 feet), indoors

Maximum rated voltage to earth

600V

Dielectric strength

5.4kVrms

Power supply

Rated supply voltage 1.5VDC×2 Two AA size batteries

Maximum rated power

300mVA

Continuous operating time*

Approx.70 hours(Power ON, Standby state, using R6P manganese battery)

*Battery life

Auto Power Off

(This function can not Be canceled.)

The power will be turned off automatically if the Instrument remains idle

for 15 minutes after the power is turned on. To reset, turn the power on

again using the Power ON switch.

Cable length

Approx. 0.7m

Dimensions and mass

Approx. 70W×75H×30Dmm(2.76W×2.95H×1.18D)

(excluding projections), Approx. 200g(7.1oz)

Applicable standards

Safety EN61010-1:2001,EN61010-031:2002

Pollution degree2, Measurement category CAT III(600V)(anticipated

transient overvoltage 6000V)

EMC EN61326:1997+A1:1998+A2:2001


Test operation

1. Phase Detection

CAUTION ! HIGH VOLTAGE !

(1)Connection:

Connect the three non-contact alligator clips to the three

phase power cables.

(2)The symbol or each clip should be placed at the center of each cables.

(3)Press “ON”,lightA,B,C flashes once to power on the tester.

(4)In case the A,B,C are lit up , R is on if positive CW is detected.

If in negative CCW, L is on.

If one or more of light A,B,C does not light up , it means the relevant phase is open. In this case, R or L does not represent the indication.

(5)Press “OFF” to shut down the tester after use

2.Live Voltage Detection

CAUTION ! HIGH VOLTAGE !

(1)Connect any of the alligator clips to the conductor. If the  conductor is powered on (Voltage within 70~600V AC),the relevant light A,B,C should light up.This can quickly determine if the conductor is powered on.

(2)Clips and lights reference table

Clips

 Lights

A (yellow ,left)

Light A

B(green ,middle)

Light B

C(red , right)

Light C